{"id":84721,"date":"2026-11-09T11:47:09","date_gmt":"2026-11-09T10:47:09","guid":{"rendered":"https:\/\/wordpress.p716985.webspaceconfig.de\/?page_id=84721"},"modified":"2026-11-09T11:47:09","modified_gmt":"2026-11-09T10:47:09","slug":"old-buildings","status":"publish","type":"page","link":"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/","title":{"rendered":"Old Buildings"},"content":{"rendered":"<p><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-1 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap\" style=\"max-width:1185.6px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><nav class=\"fusion-breadcrumbs fusion-breadcrumbs-1\" style=\"--awb-margin-top:1%;--awb-breadcrumb-sep:&#039;\/&#039;;\" aria-label=\"Breadcrumb\"><nav aria-label=\"breadcrumbs\" class=\"rank-math-breadcrumb\"><p><span class=\"last\">Home<\/span><\/p><\/nav><\/nav><div class=\"fusion-title title fusion-title-1 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-one\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;\"><h1 class=\"fusion-title-heading title-heading-center fusion-responsive-typography-calculated\" style=\"margin:0;--fontSize:42;line-height:1;\">Heat Pump Applications in Residential Old Buildings<\/h1><\/div><div class=\"fusion-text fusion-text-1\"><p><strong>Heat pumps can provide space heating and domestic hot water in older residential buildings, including homes with existing radiators. Suitability depends on the building\u2019s heat losses, required heating-water temperature and installation conditions. Building age alone does not determine whether a heat pump will work efficiently.<\/strong><\/p>\n<p>A heat pump is an electrically powered heating system that transfers energy from outdoor air, the ground or groundwater into usable heat. Domestic hot water means heated drinking water for taps, baths and showers. A suitable system can replace an existing boiler while retaining compatible heating components.<\/p>\n<p>For an older home, the starting point is its present condition: the walls, roof, windows, radiators and available equipment space. This guide explains how those existing features affect suitability and which findings deserve closer investigation before choosing equipment.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1185.6px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion-flex-column\" style=\"--awb-padding-top:1%;--awb-padding-right:2%;--awb-padding-left:2%;--awb-overflow:hidden;--awb-bg-color:#fff042;--awb-bg-color-hover:#fff042;--awb-bg-size:cover;--awb-border-radius:16px 16px 16px 16px;--awb-width-large:800px;--awb-margin-top-large:0px;--awb-spacing-right-large:2%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:2%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-2 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-paragraph blink-heading\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:20px;\"><p class=\"fusion-title-heading title-heading-center title-heading-tag fusion-responsive-typography-calculated\" style=\"margin:0;text-transform:uppercase;font-size:1em;--fontSize:20;line-height:1.8;\"><strong>Configure your personalized heat pump system!<\/strong><\/p><\/div><div class=\"fusion-builder-row fusion-builder-row-inner fusion-row fusion-flex-align-items-stretch fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"--awb-flex-grow:0;--awb-flex-grow-medium:0;--awb-flex-grow-small:0;--awb-flex-shrink:0;--awb-flex-shrink-medium:0;--awb-flex-shrink-small:0;width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-0 fusion_builder_column_inner_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:-5px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-2\" style=\"--awb-margin-left:2%;\"><p style=\"text-align: left;\">Plan your heat pump system with iDM Energiesysteme. Discover efficient heating, cooling, and hot water solutions for new buildings, renovations, and modern energy systems. Configure and personalize your iDM heat pump solution in just a few clicks.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-1 fusion_builder_column_inner_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:66.666666666667%;--awb-margin-top-large:0px;--awb-spacing-right-large:2.88%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:2.88%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-3\"><div style=\"display: flex; align-items: center; gap: 15px; flex-wrap: wrap;\">\n<div style=\"display: flex;\"><img decoding=\"async\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-73518 aligncenter\" style=\"width: 50px; height: 50px; border-radius: 50%; border: 2px solid #000000;\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/07\/thomas-portrait-150x150.jpg\" alt=\"Thomas Pletzer\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/thomas-portrait-66x66.jpg 66w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/thomas-portrait-150x150.jpg 150w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/thomas-portrait-scaled.jpg 2560w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-73509 aligncenter\" style=\"width: 50px; height: 50px; border-radius: 50%; border: 2px solid #000000;\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/07\/matthias-portrait-150x150.jpg\" alt=\"Matthias Steiner\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/matthias-portrait-66x66.jpg 66w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/matthias-portrait-150x150.jpg 150w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/matthias-portrait-scaled.jpg 1707w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-73500 aligncenter\" style=\"width: 50px; height: 50px; border-radius: 50%; border: 2px solid #000000;\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/07\/christian-hutter-portrait-150x150.jpg\" alt=\"Christian Hutter\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/christian-hutter-portrait-66x66.jpg 66w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/christian-hutter-portrait-150x150.jpg 150w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/christian-hutter-portrait-scaled.jpg 1707w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-73491 aligncenter\" style=\"width: 50px; height: 50px; border-radius: 50%; border: 2px solid #000000;\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/07\/adrian-portrait-150x150.jpg\" alt=\"Adrian Egger\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/adrian-portrait-66x66.jpg 66w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/adrian-portrait-150x150.jpg 150w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/adrian-portrait-scaled.jpg 1707w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n<div style=\"color: #000000; line-height: 0.7; margin-left: 2%;\"><strong style=\"display: block;\">CONNECT WITH OUR EXPERTS<\/strong><br \/>\n<span style=\"opacity: 0.8;\">50+ Years of Heat Pumps Experience<\/span><\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-2 fusion_builder_column_inner_1_3 1_3 fusion-flex-column fusion-flex-align-self-center\" style=\"--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:5.76%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-column\"><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-1 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/konfigurator.myidm.at\/#\/?lang=EN\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Configure Now!<\/span><\/a><\/div><div class=\"fusion-text fusion-text-4 fusion-text-no-margin\" style=\"--awb-content-alignment:center;--awb-margin-bottom:0px;\"><p><strong>OR<\/strong><\/p>\n<\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-2 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/wordpress.p716985.webspaceconfig.de\/en\/enquiry\/\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Contact Us Now!<\/span><\/a><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:2%;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-content-wrap\" style=\"max-width:calc( 1140px + 30px );margin-left: calc(-30px \/ 2 );margin-right: calc(-30px \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:15px;--awb-margin-bottom-large:80px;--awb-spacing-left-large:15px;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:15px;--awb-spacing-left-medium:15px;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:15px;--awb-spacing-left-small:15px;\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-5\">\n<\/div><div class=\"fusion-text fusion-text-6\"><div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table of Contents<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewBox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewBox=\"0 0 24 24\" version=\"1.2\" baseProfile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1 ' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#Can_a_heat_pump_work_in_an_old_residential_building\" >Can a heat pump work in an old residential building?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#Which_building_characteristics_determine_heat_pump_suitability\" >Which building characteristics determine heat pump suitability?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#Can_existing_radiators_provide_enough_heat\" >Can existing radiators provide enough heat?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#Does_an_old_building_need_insulation_before_a_heat_pump\" >Does an old building need insulation before a heat pump?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#Which_heat_source_fits_an_older_property\" >Which heat source fits an older property?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#How_much_electricity_will_a_heat_pump_use_in_an_old_building\" >How much electricity will a heat pump use in an old building?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#Which_iDM_heat_pumps_are_relevant_to_older_buildings\" >Which iDM heat pumps are relevant to older buildings?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#What_else_do_owners_ask_about_heat_pumps_in_old_buildings\" >What else do owners ask about heat pumps in old buildings?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/p716985.onelogin.de\/en\/heat-pump-applications\/residential\/old-buildings\/#How_can_you_assess_your_old_building_with_iDM\" >How can you assess your old building with iDM?<\/a><\/li><\/ul><\/nav><\/div>\n<h2><span class=\"ez-toc-section\" id=\"Can_a_heat_pump_work_in_an_old_residential_building\"><\/span>Can a heat pump work in an old residential building?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>A heat pump can heat an old residential building when its output matches the building\u2019s heat losses and the heating system delivers sufficient warmth at suitable water temperatures. Construction date alone does not establish efficiency, comfort or the necessary upgrades.<\/strong><\/p>\n<p>Measured results demonstrate that older buildings can support efficient heat pump operation. Fraunhofer ISE, Germany\u2019s Fraunhofer Institute for Solar Energy Systems, monitored 77 heat pump installations in houses containing one to three dwellings. The properties included buildings dating back to 1826, with conditions ranging from unrefurbished to comprehensively improved.<\/p>\n<p>The annual seasonal performance factor, or <strong>SPF<\/strong>, measures heat supplied divided by electricity consumed over a year within a defined measurement boundary. German-language guidance calls this annual value <em>Jahresarbeitszahl<\/em>, abbreviated <strong>JAZ<\/strong>.<\/p>\n<p>The study\u2019s main 2024 evaluation reported:<\/p>\n<\/div>\n<div class=\"table-2\" style=\"--awb-margin-bottom:2%;\">\n<table style=\"width: 100%; height: 288px;\" width=\"100%\">\n<thead>\n<tr>\n<th style=\"width: 25.2641%; text-align: left;\">Heat source<\/th>\n<th style=\"width: 25.088%;\" align=\"right\">Systems evaluated in 2024<\/th>\n<th style=\"width: 20.8627%;\" align=\"right\">Measured annual SPF<\/th>\n<th style=\"width: 27.8169%;\" align=\"right\">Reported average<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 25.2641%;\">Outdoor air<\/td>\n<td style=\"width: 25.088%;\" align=\"right\">49<\/td>\n<td style=\"width: 20.8627%;\" align=\"right\">2.6\u20134.9<\/td>\n<td style=\"width: 27.8169%;\" align=\"right\">3.4<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 25.2641%;\">Ground, using borehole probes<\/td>\n<td style=\"width: 25.088%;\" align=\"right\">13<\/td>\n<td style=\"width: 20.8627%;\" align=\"right\">3.6\u20135.4<\/td>\n<td style=\"width: 27.8169%;\" align=\"right\">Not stated in the project summary<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-7\"><p>An SPF of 3.4 represents 3.4 units of heat supplied per unit of electricity within the study\u2019s measurement boundary. Researchers found no relationship between building age and annual efficiency in this sample. These German field results demonstrate feasibility; they do not predict the performance of a particular Austrian home.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Which_building_characteristics_determine_heat_pump_suitability\"><\/span>Which building characteristics determine heat pump suitability?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Heat pump suitability depends on the building\u2019s heat losses, the output of existing radiators, the condition of heating pipes and the available installation space. Assess these characteristics together, because improving one component does not automatically resolve limitations in another component.<\/strong><\/p>\n<p>The <strong>design heat load<\/strong> is the heating power needed to maintain specified indoor temperatures under local winter design conditions. It is expressed in kilowatts, or <strong>kW<\/strong>. Annual heat demand is an energy quantity expressed in kilowatt-hours, or <strong>kWh<\/strong>. A building needs both assessments: power for equipment sizing and annual energy for consumption estimates.<\/p>\n<p>Use the following assessment to identify the building\u2019s limiting conditions.<\/p>\n<\/div>\n<div class=\"table-2\" style=\"--awb-margin-bottom:2%;\">\n<table style=\"width: 100%; height: 288px;\" width=\"100%\">\n<thead>\n<tr>\n<th style=\"width: 31.9542%; text-align: left;\">Existing characteristic<\/th>\n<th style=\"width: 36.6197%; text-align: left;\">What to establish<\/th>\n<th style=\"width: 30.5458%; text-align: left;\">Why it matters<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 31.9542%;\">Building fabric: walls, roof, windows and floors<\/td>\n<td style=\"width: 36.6197%;\">Heat losses from individual rooms, including ventilation losses<\/td>\n<td style=\"width: 30.5458%;\">Determines how much heating each room needs<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.9542%;\">Radiators: devices that release heat from hot water into rooms<\/td>\n<td style=\"width: 36.6197%;\">Available output at the proposed water temperatures<\/td>\n<td style=\"width: 30.5458%;\">Determines whether existing radiators can maintain comfort<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.9542%;\">Heating distribution: pipes, valves and circulation equipment<\/td>\n<td style=\"width: 36.6197%;\">Condition and ability to deliver the required water flows<\/td>\n<td style=\"width: 30.5458%;\">Establishes which components can remain<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 31.9542%;\">Installation space<\/td>\n<td style=\"width: 36.6197%;\">Equipment access, indoor dimensions and a feasible heat-source location<\/td>\n<td style=\"width: 30.5458%;\">Establishes whether the proposed system physically fits<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-8\"><p>A room-by-room assessment is especially useful where improvements have been uneven. New windows in the living room do not establish the heating requirement of an unchanged bathroom or an exposed room beneath the roof.<\/p>\n<p>Ask the designer to check heat pump output at the project\u2019s actual winter conditions. Also check the equipment\u2019s minimum output during milder weather: excessive capacity can cause repeated starting and stopping.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Can_existing_radiators_provide_enough_heat\"><\/span>Can existing radiators provide enough heat?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Existing radiators can work with a heat pump when they deliver each room\u2019s required heating output at the selected flow temperature, meaning the temperature of water entering the heating circuit. Check individual rooms before deciding which radiators need replacing first.<\/strong><\/p>\n<p>Radiator output depends on its dimensions, construction and operating temperatures. A radiator previously supplied with hotter boiler water may still provide sufficient heat at a lower temperature, particularly where the room\u2019s heat losses have already been reduced.<\/p>\n<p>Klimaaktiv, Austria\u2019s federal climate and energy-transition initiative, confirms that modern heat pumps can work with radiators. Its guidance identifies larger radiators and suitable radiator fans as ways to increase heat delivery at lower water temperatures.<\/p>\n<h3>Is 55\u00b0C a universal suitability limit?<\/h3>\n<p><strong>No. A flow temperature of 55\u00b0C is a useful assessment reference, not a universal boundary between working and non-working systems.<\/strong><\/p>\n<p>Energieagentur Tirol, a regional Austrian energy-advice organisation, recommends keeping flow temperatures at or below 50\u00b0C for efficient operation. Klimaaktiv discusses modern heat pump operation with radiators at temperatures up to 55\u00b0C. Both support the same direction: reduce the temperature required to keep rooms comfortable.<\/p>\n<p>A requirement above 55\u00b0C calls for closer assessment of radiator improvements, heat losses and the selected heat pump\u2019s performance. A product\u2019s maximum temperature does not establish its annual electricity consumption.<\/p>\n<h3>How do you identify the room that limits the system?<\/h3>\n<p>Compare each room\u2019s calculated heating requirement with its radiator output at the proposed operating temperatures. Energieinstitut Vorarlberg, an Austrian energy-advice organisation, notes that replacing the radiator in the most demanding room can sometimes allow lower temperatures throughout the system.<\/p>\n<\/div><div class=\"fusion-image-element awb-imageframe-style awb-imageframe-style-below awb-imageframe-style-1\" style=\"text-align:center;--awb-margin-top:3%;--awb-margin-bottom:3%;--awb-caption-title-font-family:var(--h6_typography-font-family);--awb-caption-title-font-weight:var(--h6_typography-font-weight);--awb-caption-title-font-style:var(--h6_typography-font-style);--awb-caption-title-size:var(--h6_typography-font-size);--awb-caption-title-transform:var(--h6_typography-text-transform);--awb-caption-title-line-height:var(--h6_typography-line-height);--awb-caption-title-letter-spacing:var(--h6_typography-letter-spacing);\"><span class=\" fusion-imageframe imageframe-none imageframe-1 hover-type-none\" style=\"border:3px solid #333333;\"><img decoding=\"async\" width=\"1148\" height=\"950\" alt=\"Heat Pumps in Old Buildings\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/11\/heat-pumps-old-buildings.webp\" class=\"img-responsive wp-image-84727\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/11\/heat-pumps-old-buildings-200x166.webp 200w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/11\/heat-pumps-old-buildings-400x331.webp 400w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/11\/heat-pumps-old-buildings-600x497.webp 600w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/11\/heat-pumps-old-buildings-800x662.webp 800w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/11\/heat-pumps-old-buildings.webp 1148w\" sizes=\"(max-width: 1024px) 100vw, (max-width: 640px) 100vw, 1148px\" \/><\/span><div class=\"awb-imageframe-caption-container\" style=\"text-align:center;\"><div class=\"awb-imageframe-caption\"><h6 class=\"awb-imageframe-caption-title\"> <\/h6><p class=\"awb-imageframe-caption-text\">Radiator suitability is checked room by room. Heat pump capacity, pipework and site feasibility require separate assessment.<\/p><\/div><\/div><\/div><div class=\"fusion-text fusion-text-9\"><p>For a <strong>hypothetical example<\/strong>, a room needs 1.5 kW at winter design conditions, while its radiator supplies 1.0 kW at the proposed temperatures. The 0.5 kW shortfall requires a larger or different heat emitter, reduced room heat loss, or a revised operating temperature. This calculation identifies a specific limitation without assuming every radiator needs replacement.<\/p>\n<h3>Can existing settings exaggerate the temperature requirement?<\/h3>\n<p><strong>Yes. Poor water distribution or an unnecessarily high control setting can obscure what the building actually needs.<\/strong><\/p>\n<p>Hydraulic balancing means adjusting water flows so each heating circuit receives its designed supply. Have the installer assess this alongside the <strong>heating curve<\/strong>, the control relationship between outdoor temperature and heating-water temperature. A supervised temperature trial can provide useful observations, but a mild-weather test does not prove performance at winter design conditions.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Does_an_old_building_need_insulation_before_a_heat_pump\"><\/span>Does an old building need insulation before a heat pump?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>An old building does not automatically need complete insulation before a heat pump installation. Insulation reduces heat loss, but the necessary improvements depend on existing room requirements and radiator output. Targeted measures can improve suitability without requiring comprehensive building refurbishment.<\/strong><\/p>\n<p>Fraunhofer ISE\u2019s field research supports efficient heat pump operation in older buildings without requiring every property to reach new-build energy performance. That finding does not mean insulation has no value; it means suitability requires assessment of the actual building.<\/p>\n<p>The <strong>building envelope<\/strong> is the collection of walls, roof, windows and floors separating heated rooms from colder surroundings. Improving an envelope component reduces heat loss through that component.<\/p>\n<p>The most useful improvement for heat pump operation may be the measure that addresses a limiting room. Reducing total building demand does not necessarily lower the temperature needed by an unchanged room with an undersized radiator. Energieinstitut Vorarlberg highlights this issue in partially refurbished buildings.<\/p>\n<p>For the suitability assessment, request two clearly separated results:<\/p>\n<ul>\n<li>The calculated heating requirement in the building\u2019s current condition.<\/li>\n<li>The calculated requirement after any improvements already planned.<\/li>\n<\/ul>\n<p>Those results show how planned work changes equipment requirements. Detailed construction sequencing belongs in the renovation project plan.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Which_heat_source_fits_an_older_property\"><\/span>Which heat source fits an older property?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>The appropriate heat pump source depends on access to outdoor air, suitable ground or usable groundwater at the property. Existing gardens, neighbouring homes, drilling access and equipment space influence feasibility. Compare source options alongside the building\u2019s required heating water temperature.<\/strong><\/p>\n<p>The heat source supplies the environmental energy collected by the heat pump. Existing site conditions can make one source more practical than another.<\/p>\n<\/div>\n<div class=\"table-2\" style=\"--awb-margin-bottom:2%;\">\n<table style=\"width: 100%;\" width=\"100%\">\n<thead>\n<tr>\n<th style=\"width: 9.0669%; text-align: left;\">Heat source<\/th>\n<th style=\"width: 46.919%; text-align: left;\">How heat is collected<\/th>\n<th style=\"width: 43.1338%; text-align: left;\">Particular checks for an older property<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 9.0669%;\">Outdoor air<\/td>\n<td style=\"width: 46.919%;\">An air-source heat pump extracts energy from surrounding air<\/td>\n<td style=\"width: 43.1338%;\">Outdoor-unit location, airflow, sound, drainage and service access<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 9.0669%;\">Ground<\/td>\n<td style=\"width: 46.919%;\">Buried collector pipes or probes installed in drilled boreholes collect ground heat<\/td>\n<td style=\"width: 43.1338%;\">Excavation or drilling access, underground services and ground suitability<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 9.0669%;\">Groundwater<\/td>\n<td style=\"width: 46.919%;\">A well arrangement supplies groundwater for heat extraction<\/td>\n<td style=\"width: 43.1338%;\">Water availability, quality, well feasibility and applicable permissions<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-10\"><p>Energieagentur Tirol identifies ground conditions, groundwater availability and sound in densely built areas as material source-selection constraints. A small garden alone does not establish whether ground-source heating is feasible; the available source arrangement needs investigation.<\/p>\n<h3>What changes in cold weather?<\/h3>\n<p>Air-source heat pumps face colder source temperatures as outdoor conditions cool. The designer must check available heating output and efficiency at the location\u2019s winter conditions, including the energy required for defrosting when frost forms on the outdoor heat exchanger.<\/p>\n<p>For Austrian projects, confirm applicable building, sound and water-related requirements with the relevant authorities. For a heritage-listed property, discuss equipment visibility and alterations to historic fabric before finalising the installation position. Avoid assuming that one approval arrangement applies across Austria, Germany and Switzerland.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_much_electricity_will_a_heat_pump_use_in_an_old_building\"><\/span>How much electricity will a heat pump use in an old building?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>A heat pump\u2019s annual electricity demand depends on the heat it supplies and its annual system efficiency. An older home with higher heat losses requires more heat. Lowering those losses and improving efficiency address separate parts of the consumption calculation.<\/strong><\/p>\n<p>The basic relationship is:<\/p>\n<p><strong>Annual electricity consumption = annual heat supplied \u00f7 annual SPF<\/strong><\/p>\n<p>Keep the calculation boundary consistent. A figure covering space heating and domestic hot water needs an SPF covering those same services. Identify whether the electricity total includes source pumps, controls, circulation equipment and electric supplementary heating.<\/p>\n<p>A <strong>coefficient of performance<\/strong>, or <strong>COP<\/strong>, describes efficiency at a specified operating point. It cannot replace a site-specific annual performance estimate. Klimaaktiv recommends documenting the expected annual performance and providing heat and electricity measurement for checking operation.<\/p>\n<h3>What does efficiency change in a consumption estimate?<\/h3>\n<p>The following <strong>hypothetical calculation<\/strong> assumes 24,000 kWh of annual heat supplied and an electricity price of \u20ac0.30\/kWh. These are illustrative inputs, not an Austrian tariff quotation or a prediction for your property.<\/p>\n<\/div>\n<div class=\"table-2\" style=\"--awb-margin-bottom:2%;\">\n<table style=\"width: 100%;\" width=\"100%\">\n<thead>\n<tr>\n<th style=\"width: 26.4987%;\" align=\"right\">Assumed annual SPF<\/th>\n<th style=\"width: 40.4865%;\" align=\"right\">Calculated annual electricity use<\/th>\n<th style=\"width: 32.0591%;\" align=\"right\">Calculated electricity cost<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 26.4987%;\" align=\"right\">2.5<\/td>\n<td style=\"width: 40.4865%;\" align=\"right\">9,600 kWh<\/td>\n<td style=\"width: 32.0591%;\" align=\"right\">\u20ac2,880<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 26.4987%;\" align=\"right\">3.5<\/td>\n<td style=\"width: 40.4865%;\" align=\"right\">Approximately 6,857 kWh<\/td>\n<td style=\"width: 32.0591%;\" align=\"right\">Approximately \u20ac2,057<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 26.4987%;\" align=\"right\">4.5<\/td>\n<td style=\"width: 40.4865%;\" align=\"right\">Approximately 5,333 kWh<\/td>\n<td style=\"width: 32.0591%;\" align=\"right\">Approximately \u20ac1,600<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-11\"><p>The scenarios hold heat demand constant to isolate the effect of efficiency. They are not a promised performance range. Fixed electricity charges, maintenance and consumption outside the chosen system boundary are excluded.<\/p>\n<p>Existing fuel bills also need interpretation. Gas or oil consumption records energy purchased; the heating system delivers less useful heat because conversion and system losses occur. An assessment must account for those losses before translating fuel consumption into future heat pump electricity demand.<\/p>\n<h3>What determines whether the investment is worthwhile?<\/h3>\n<p>A meaningful comparison combines the complete installed price with expected operating costs. Request an itemised quotation covering:<\/p>\n<ul>\n<li>Heat pump equipment, controls and the required hot water arrangement.<\/li>\n<li>Outdoor-unit works, collectors, drilling or wells, as applicable.<\/li>\n<li>Necessary radiator, pipework and electrical alterations.<\/li>\n<li>Design, commissioning, documentation and agreed aftercare.<\/li>\n<\/ul>\n<p>Klimaaktiv\u2019s installation guidance supports defining the requirements before comparing quotations. A property-specific comparison needs the same comfort assumptions, heating demand and scope of work for every option.<\/p>\n<p>No single payback period applies to all older homes. The result depends on the project cost, the heating system being replaced, achieved efficiency, energy prices and any support actually available to the project.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"Which_iDM_heat_pumps_are_relevant_to_older_buildings\"><\/span>Which iDM heat pumps are relevant to older buildings?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>iDM heat pump selection follows the building assessment: AERO addresses air sources, TERRA ground sources, iPUMP integrated-storage ranges, MAX larger capacities and NANO apartment applications. These names describe overlapping product characteristics, so suitability requires checking the exact model and configuration.<\/strong><\/p>\n<p>iDM Energiesysteme GmbH is an Austrian heat pump manufacturer. Its ranges provide different starting points for equipment selection.<\/p>\n<\/div>\n<div class=\"table-2\" style=\"--awb-margin-bottom:2%;\">\n<table style=\"width: 100%; height: 144px;\" width=\"100%\">\n<thead>\n<tr>\n<th style=\"width: 7.21831%; text-align: left;\">iDM range<\/th>\n<th style=\"width: 30.7218%; text-align: left;\">What the range identifies<\/th>\n<th style=\"width: 61.1796%; text-align: left;\">Relevance to an older residential building<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"width: 7.21831%;\"><strong>AERO<\/strong><\/td>\n<td style=\"width: 30.7218%;\">Air-source heat pumps<\/td>\n<td style=\"width: 61.1796%;\">Consider where an appropriate air-source installation location is available. Check output at the building\u2019s winter temperatures.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 7.21831%;\"><strong>TERRA<\/strong><\/td>\n<td style=\"width: 30.7218%;\">Heat pumps using ground or groundwater energy<\/td>\n<td style=\"width: 61.1796%;\">Consider after establishing that the property supports the required collector, borehole or well arrangement.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 7.21831%;\"><strong>iPUMP<\/strong><\/td>\n<td style=\"width: 30.7218%;\">Integrated-storage product ranges, including relevant ONE models<\/td>\n<td style=\"width: 61.1796%;\">Consider where combining heat pump equipment with hot water storage suits the available indoor space and demand.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 7.21831%;\"><strong>MAX<\/strong><\/td>\n<td style=\"width: 30.7218%;\">Larger-capacity heat pump solutions<\/td>\n<td style=\"width: 61.1796%;\">Consider when the calculated residential heating requirement calls for larger equipment. Building age alone does not justify higher capacity.<\/td>\n<\/tr>\n<tr>\n<td style=\"width: 7.21831%;\"><strong>NANO<\/strong><\/td>\n<td style=\"width: 30.7218%;\">Apartment-level heat pump solutions, including iPUMP N5<\/td>\n<td style=\"width: 61.1796%;\">Consider where an existing building requires a dwelling-level solution with a properly designed heat-source supply.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<div class=\"fusion-text fusion-text-12\"><p>These descriptions follow iDM\u2019s product information. AERO and TERRA identify source-related categories; integrated storage and capacity describe different selection dimensions.<\/p>\n<h3>Does a high maximum temperature establish suitability?<\/h3>\n<p><strong>No. Maximum flow temperature establishes an equipment capability; suitability also depends on available output and efficiency under the project\u2019s operating conditions.<\/strong><\/p>\n<p>For example, iDM lists a maximum heating flow temperature of <strong>70\u00b0C for the AERO ALM 6-15<\/strong>. That specification does not establish its annual SPF in a particular radiator system. Request the selected model\u2019s performance at the required outdoor and heating-water temperatures.<\/p>\n<p>For NANO, the source arrangement is part of the design. The iPUMP N5 must be assessed with its proposed energy supply and apartment demand; its compact dimensions alone do not establish replacement suitability.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"What_else_do_owners_ask_about_heat_pumps_in_old_buildings\"><\/span>What else do owners ask about heat pumps in old buildings?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Heat pump compatibility extends beyond room heating: existing hot water storage, supplementary heating and summer cooling need separate checks. Keeping a component depends on its technical suitability. A heating assessment therefore cannot automatically confirm every additional function of the system.<\/strong><\/p>\n<h3>Can I keep my existing hot water cylinder?<\/h3>\n<p><strong>An existing cylinder can remain when its condition, storage capacity and heat-transfer performance suit the proposed heat pump.<\/strong><\/p>\n<p>A cylinder\u2019s heat exchanger transfers heat between separate fluids. Energieagentur Tirol advises checking existing cylinders for heat pump compatibility because an unsuitable heat exchanger can restrict operation and efficiency.<\/p>\n<p>The designer must also specify a suitable drinking-water hygiene strategy. Room-heating temperature targets are not instructions for changing stored drinking-water temperatures.<\/p>\n<h3>Do I have to retain the old boiler?<\/h3>\n<p><strong>Retaining the old boiler is a design choice, not an automatic requirement for an older building.<\/strong><\/p>\n<p>A hybrid arrangement combines a heat pump with another heat generator, such as a boiler. Assess it against a system designed to meet demand without that boiler, including any electric supplementary heater. Document when each heat source operates and include the additional equipment and servicing in the comparison. Klimaaktiv discusses heat pump and boiler combinations as a distinct system arrangement. <a href=\"https:\/\/www.klimaaktiv.at\/fileadmin\/Bibliothek\/Publikationen\/2026_Wegweiser_Waermepumpe.pdf?utm_source=chatgpt.com\" target=\"_blank\" rel=\"noopener\">klimaaktiv.at<\/a><\/p>\n<h3>Can the heat pump cool rooms through existing radiators?<\/h3>\n<p><strong>Cooling requires compatible equipment and heat distribution; existing radiators do not automatically provide a suitable cooling system.<\/strong><\/p>\n<p>Cold radiator surfaces can cause condensation, meaning moisture from the air forms water on the surface. Cooling therefore needs a separate assessment of suitable emitters, pipe insulation and moisture control. Energieinstitut Vorarlberg specifically identifies condensation as a limitation when cooling through existing heating surfaces.<\/p>\n<h2><span class=\"ez-toc-section\" id=\"How_can_you_assess_your_old_building_with_iDM\"><\/span>How can you assess your old building with iDM?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><strong>Start your heat pump assessment with evidence about the building you have: room dimensions, radiator details, heating records and completed improvements. These inputs help an iDM specialist identify suitable options and explain which additional calculations are needed before equipment selection.<\/strong><\/p>\n<p>Prepare the following information for your consultation:<\/p>\n<ul>\n<li>Floor plans, heated areas and the property\u2019s location.<\/li>\n<li>Available fuel or heating-energy records.<\/li>\n<li>Radiator dimensions and photographs of the existing heating system.<\/li>\n<li>Records of insulation, window replacements and planned improvements.<\/li>\n<li>Photographs and dimensions of potential indoor and outdoor equipment locations.<\/li>\n<\/ul>\n<p>The most useful outcome is a documented answer to three questions: what can remain, what requires improvement and which heat pump configuration fits the assessed building.<\/p>\n<p>For an older single-family or two-family home, start with iDM\u2019s heat pump configurator. Larger residential projects benefit from an individual consultation.<\/p>\n<\/div><\/div><\/div><\/div><\/div><div class=\"fusion-fullwidth fullwidth-box fusion-builder-row-4 fusion-flex-container has-pattern-background has-mask-background nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" style=\"--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;\" ><div class=\"fusion-builder-row fusion-row fusion-flex-align-items-stretch fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"max-width:1185.6px;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion-flex-column\" style=\"--awb-padding-top:1%;--awb-padding-right:2%;--awb-padding-left:2%;--awb-overflow:hidden;--awb-bg-color:#fff042;--awb-bg-color-hover:#fff042;--awb-bg-size:cover;--awb-border-radius:16px 16px 16px 16px;--awb-width-large:800px;--awb-margin-top-large:0px;--awb-spacing-right-large:2%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:2%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-title title fusion-title-3 fusion-sep-none fusion-title-center fusion-title-text fusion-title-size-paragraph blink-heading\" style=\"--awb-margin-top-small:10px;--awb-margin-right-small:0px;--awb-margin-bottom-small:10px;--awb-margin-left-small:0px;--awb-font-size:20px;\"><p class=\"fusion-title-heading title-heading-center title-heading-tag fusion-responsive-typography-calculated\" style=\"margin:0;text-transform:uppercase;font-size:1em;--fontSize:20;line-height:1.8;\"><strong>Configure your personalized heat pump system!<\/strong><\/p><\/div><div class=\"fusion-builder-row fusion-builder-row-inner fusion-row fusion-flex-align-items-stretch fusion-flex-justify-content-center fusion-flex-content-wrap\" style=\"--awb-flex-grow:0;--awb-flex-grow-medium:0;--awb-flex-grow-small:0;--awb-flex-shrink:0;--awb-flex-shrink-medium:0;--awb-flex-shrink-small:0;width:104% !important;max-width:104% !important;margin-left: calc(-4% \/ 2 );margin-right: calc(-4% \/ 2 );\"><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-3 fusion_builder_column_inner_1_1 1_1 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:-5px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-13\" style=\"--awb-margin-left:2%;\"><p style=\"text-align: left;\">Plan your heat pump system with iDM Energiesysteme. Discover efficient heating, cooling, and hot water solutions for new buildings, renovations, and modern energy systems. Configure and personalize your iDM heat pump solution in just a few clicks.<\/p>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-4 fusion_builder_column_inner_2_3 2_3 fusion-flex-column\" style=\"--awb-bg-size:cover;--awb-width-large:66.666666666667%;--awb-margin-top-large:0px;--awb-spacing-right-large:2.88%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:2.88%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column\"><div class=\"fusion-text fusion-text-14\"><div style=\"display: flex; align-items: center; gap: 15px; flex-wrap: wrap;\">\n<div style=\"display: flex;\"><img decoding=\"async\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-73518 aligncenter\" style=\"width: 50px; height: 50px; border-radius: 50%; border: 2px solid #000000;\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/07\/thomas-portrait-150x150.jpg\" alt=\"Thomas Pletzer\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/thomas-portrait-66x66.jpg 66w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/thomas-portrait-150x150.jpg 150w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/thomas-portrait-scaled.jpg 2560w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-73509 aligncenter\" style=\"width: 50px; height: 50px; border-radius: 50%; border: 2px solid #000000;\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/07\/matthias-portrait-150x150.jpg\" alt=\"Matthias Steiner\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/matthias-portrait-66x66.jpg 66w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/matthias-portrait-150x150.jpg 150w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/matthias-portrait-scaled.jpg 1707w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-73500 aligncenter\" style=\"width: 50px; height: 50px; border-radius: 50%; border: 2px solid #000000;\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/07\/christian-hutter-portrait-150x150.jpg\" alt=\"Christian Hutter\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/christian-hutter-portrait-66x66.jpg 66w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/christian-hutter-portrait-150x150.jpg 150w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/christian-hutter-portrait-scaled.jpg 1707w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><br \/>\n<img decoding=\"async\" width=\"150\" height=\"150\" class=\"size-thumbnail wp-image-73491 aligncenter\" style=\"width: 50px; height: 50px; border-radius: 50%; border: 2px solid #000000;\" src=\"http:\/\/wordpress.p716985.webspaceconfig.de\/wp-content\/uploads\/2026\/07\/adrian-portrait-150x150.jpg\" alt=\"Adrian Egger\" srcset=\"https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/adrian-portrait-66x66.jpg 66w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/adrian-portrait-150x150.jpg 150w, https:\/\/p716985.onelogin.de\/wp-content\/uploads\/2026\/07\/adrian-portrait-scaled.jpg 1707w\" sizes=\"(max-width: 150px) 100vw, 150px\" \/><\/div>\n<div style=\"color: #000000; line-height: 0.7; margin-left: 2%;\"><strong style=\"display: block;\">CONNECT WITH OUR EXPERTS<\/strong><br \/>\n<span style=\"opacity: 0.8;\">50+ Years of Heat Pumps Experience<\/span><\/div>\n<\/div>\n<\/div><\/div><\/div><div class=\"fusion-layout-column fusion_builder_column_inner fusion-builder-nested-column-5 fusion_builder_column_inner_1_3 1_3 fusion-flex-column fusion-flex-align-self-center\" style=\"--awb-bg-size:cover;--awb-width-large:33.333333333333%;--awb-margin-top-large:0px;--awb-spacing-right-large:5.76%;--awb-margin-bottom-large:20px;--awb-spacing-left-large:5.76%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;\" data-scroll-devices=\"small-visibility,medium-visibility,large-visibility\"><div class=\"fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-center fusion-content-layout-column\"><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-3 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/konfigurator.myidm.at\/#\/?lang=EN\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Configure Now!<\/span><\/a><\/div><div class=\"fusion-text fusion-text-15 fusion-text-no-margin\" style=\"--awb-content-alignment:center;--awb-margin-bottom:0px;\"><p><strong>OR<\/strong><\/p>\n<\/div><div style=\"text-align:center;\"><a class=\"fusion-button button-flat fusion-button-default-size button-default fusion-button-default button-4 fusion-button-default-span fusion-button-default-type\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/wordpress.p716985.webspaceconfig.de\/en\/enquiry\/\"><span class=\"fusion-button-text awb-button__text awb-button__text--default\">Contact Us Now!<\/span><\/a><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n<\/p>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":34,"featured_media":2902,"parent":84504,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"100-width.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-84721","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/pages\/84721","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/comments?post=84721"}],"version-history":[{"count":1,"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/pages\/84721\/revisions"}],"predecessor-version":[{"id":84736,"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/pages\/84721\/revisions\/84736"}],"up":[{"embeddable":true,"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/pages\/84504"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/media\/2902"}],"wp:attachment":[{"href":"https:\/\/p716985.onelogin.de\/en\/wp-json\/wp\/v2\/media?parent=84721"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}